Nanostructured microelectrodes

Product Code: 84

The newly developed neural interface nanostructured flexible multi-channel polymer implantable microelectrode chip is used to enhance the signal detection capability and biocompatibility of implanted electrodes. To advanced non-toxic polymer micro-electromechanical process technology to complete the flexible micron-scale neural electrode chip. The implanted chip has 3D multi-dimensional array of microelectrode electrodes, through the 3D printing technology in the chip surface using a special electrodeposition to form a nanostructure composite layer, with excellent detection capability.
The electrode has a mechanical strength implanted into deep brain tissue and is coated with an anti-inflammatory factor nanostructured coating so that its surface can provide mechanical and structural high bionic properties, anti-biological sticking properties and long- Inflammatory effects. Can be used for long-term implantation of deep cranial nerve recording and electrical stimulation of the application, has been tested in rodents and primates, the results show that the electrode has a very good biocompatibility and neural signal quality.

Product No. : sS74l
Dimension Value
Number of probe shaft 1
Number of electrodes 16
Probe length (A) 18.8 mm
Probe width (B) 2 mm
Probe length (C) 14.90 mm
Max shaft width (D) 996 μm
Shaft width (E) 220 μm
Tip width (F) 3μm
Distance (G) 48.4 μm
Diameter of electrode (H) 12μm
Wire width (I) 10 μm
Wire width (J) 5 μm
Electrode distance (K) 74 μm
Recording length (L) 1.11 mm

Product No. : sS150l
Dimension Value
Number of probe shaft 1
Number of electrodes 16
Probe length (A) 18.8 mm
Probe width (B) 2 mm
Probe length (C) 14.90 mm
Max shaft width (D) 996 μm
Shaft width (E) 220 μm
Tip width (F) 3 μm
Distance (G) 48.4 μm
Diameter of electrode (H) 12 μm
Wire width (I) 10 μm
Wire width (J) 5 μm
Electrode distance (K) 150 μm
Recording length (L) 2.25 mm

Product No. : sS74s
Dimension Value
Number of probe shaft 1
Number of electrodes 16
Probe length (A) 8.2 mm
Probe width (B) 2 mm
Probe length (C) 4.3 mm
Max shaft width (D) 996 μm
Shaft width (E) 220 μm
Tip width (F) 3 μm
Distance (G) 48.4 μm
Diameter of electrode (H) 12 μm
Wire width (I) 10 μm
Wire width (J) 5 μm
Electrode distance (K) 74 μm
Recording length (L) 1.11 mm

Product No. : mS74s
Dimension Value
Number of probe shaft 2
Shaft interval (T) 278 μm
Number of electrodes 16
Probe length (A) 8.2 mm
Probe width (B) 2 mm
Probe length (C) 4.3 mm
Max shaft width (D) 498 μm
Shaft width (E) 150 μm
Tip width (F) 3 μm
Distance (G) 48.4 μm
Diameter of electrode (H) 12 μm
Wire width (I) 10 μm
Wire width (J) 5 μm
Electrode distance (K) 74 μm
Recording length (L) 555 μm

Product No. : mS74l
Dimension Value
Number of probe shaft 2
Shaft interval (T) 278 μm
Number of electrodes 16
Probe length (A) 14.9 mm
Probe width (B) 2 mm
Probe length (C) 11 mm
Max shaft width (D) 498 μm
Shaft width (E) 150 μm
Tip width (F) 3 μm
Distance (G) 48.4 μm
Diameter of electrode (H) 12 μm
Wire width (I) 10 μm
Wire width (J) 5 μm
Electrode distance (K) 74 μm
Recording length (L) 555 μm